24 hour time switch | timer-switch.com
24 hour time switch at timer-switch.com
2014年4月28日星期一
2014年4月15日星期二
Ultrasonic Sensor Waterproof UB1500 30GM U V1
Ultrasonic Sensor Waterproof,ultrasonic sensor working | Timer-Switch.com
Ultrasonic Sensor Waterproof UB1500 30GM U V1
Ultrasonic Sensor Waterproof UB1500 30GM U V1
External synchronization
The sensor can be synchronised by the external application of a square wave voltage. A synchronisation pulse at the synchronisation
input starts a measuring cycle. The pulse must have a duration greater than 100 μs. The measuring cycle starts with
the falling edge of a synchronisation pulse. A low level > 1 s or an open synchronisation input will result in the normal operation
of the sensor. A high level at the synchronisation input disables the sensor. Two operating modes are available:
1. Multiple sensors can be controlled by the same synchronisation signal. The sensors are synchronised.
2. The synchronisation pulses are sent cyclically to individual sensors. The sensors operate in multiplex mode.
Internal synchronization
The synchronisation connections of up to 5 sensors capable of internal synchronisation are connected to one another. When
power is applied, these sensors will operate in multiplex mode.
The response delay increases according to the number of sensors to be synchronised. Synchronisation cannot be performed
during TEACH-IN and vice versa. The sensors must be operated in an unsynchronised manner to teach the evaluation limits.
Note:
If the option for synchronisation is not used, the synchronisation input has to be connected to ground (0V) or the sensor has to
be operated via a V1 cable connector (4-pin).
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.
Download product details Including the size,Installation information and product functionality information
Downloads PDF Ultrasonic-Sensors-UB1500-30GM-U-V1:
Ultrasonic-Sensors-UB1500-30GM-U-V1(3)
2014年4月13日星期日
Ultrasonic Sensor Circuit UB2000-30GM75 I V1 | timer-switch.com
http://www.timer-switch.com/ultrasonic-sensor-circuit-ub2000-30gm75-i-v1.html
Ultrasonic Sensor Circuit UB2000-30GM75 I V1
Ultrasonic Sensor Circuit UB2000-30GM75 I V1
Internal synchronization
The synchronisation connections of up to 5 sensors capable of internal synchronisation are connected to one another. When
power is applied, these sensors will operate in multiplex mode.
The response delay increases according to the number of sensors to be synchronised. Synchronisation cannot be performed
during TEACH-IN and vice versa. The sensors must be operated in an unsynchronised manner to teach the evaluation limits.
Note:
If the option for synchronisation is not used, the synchronisation input has to be connected to ground (0V) or the sensor has to
be operated via a V1 cable connector (4-pin).
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage – UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with – UB, A2 with + UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with – UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with – UB
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
Download product details Including the size,Installation information and product functionality information
Downloads PDF Ultrasonic-Sensors-UB2000-30GM75-I-V1:
Ultrasonic-Sensors-UB2000-30GM75-I-V1(2)
Long Distance Ultrasonic Sensor UB2000 30GM E5 V1
Long Distance Ultrasonic Sensor UB2000 30GM E5 V1
Long Distance Ultrasonic Sensor UB2000 30GM E5 V1
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points.
These are set by applying the supply voltage – UB or + UB to the TEACH-IN input.
The supply voltage must be applied to the TEACH-IN input for at least 1 s.
LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure.
Switching point A1 is taught with – UB,A2 with +UB. Five different output functions can be set.
Window mode, normally-open function.
Window mode, normally-closed function.
One switching point,normally-open function
One switching point,normally-closed function.
Detection of objet presence.
Switching point, Setting distance only after power on. The internal clock can assure can’t be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.
Download product details Including the size,Installation information and product functionality information
Downloads PDF Ultrasonic-Sensors-UB2000-30GM-E5-V1:
Ultrasonic-Sensors-UB2000-30GM-E5-V1(2)
2014年4月12日星期六
Buy Ultrasonic Sensor UB2000 30GM U V1
Buy Ultrasonic Sensor UB2000 30GM U V1
Internal synchronization
The synchronisation connections of up to 5 sensors capable of internal synchronisation are connected to one another. When
power is applied, these sensors will operate in multiplex mode.
The response delay increases according to the number of sensors to be synchronised. Synchronisation cannot be performed
during TEACH-IN and vice versa. The sensors must be operated in an unsynchronised manner to teach the evaluation limits.
Note:
If the option for synchronisation is not used, the synchronisation input has to be connected to ground (0V) or the sensor has to
be operated via a V1 cable connector (4-pin).
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage – UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with – UB, A2 with + UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with – UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with – UB
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
Download product details Including the size,Installation information and product functionality information